U bevindt zich hier: Home »

Auxiliary Gate Drive Transformer – EP7

EP7 Auxiliary Gate Drive Transformer

for SiC-MOSFET and IGBT

Model:EP7 SMD
Ae(mm2) :10 
Ref.vermogen:6 W

Deel naar:

Product Beschrijving

The TrafoPSU EP7 series is an auxiliary gate drive transformer for isolated bias supplies in half-bridge and LLC resonant stages. Built on an EP7 ferrite core with a split-bobbin — two separate winding chambers — it provides the isolated bias rail that high-side IGBT, SiC MOSFET and GaN gate drivers need, without resorting to a boot-strap or a separate isolated DC-DC brick.

Insulation is achieved by construction rather than by distance alone: the isolated winding uses FIW4 triple-insulated wire, separated from the primary by the bobbin chamber wall and a polyimide barrier film. The result is a reinforced-insulation system verified by a 4.0 kVAC dielectric test at 50 Hz with a 3 mA leakage limit. Three standard builds cover the common 24 V bias rails — 24 V → 20 V / 6 W, 24 V → 12 V / 5 W en 24 V → 48 V / 5 W.

What the specification really buys you is stability at the edges. Every picofarad across the barrier carries displacement current I = CWW × dV/dt, so at a 50 V/ns switching edge a 10 pF barrier injects roughly 0.5 A of common-mode current into the driver on every transition. Holding the barrier to 3.0 pF typical removes about 70 % of it — less driver upset, less radiated EMI, and less shoot-through risk in the half-bridge.

Replacement Options for Würth WE-AGDT Part Numbers

The TrafoPSU EP7 auxiliary gate drive transformer series offers replacement options for Würth Elektronik WE-AGDT part numbers 750318207, 750319331 en 750318616.

Each reference is supplied as its corresponding TrafoPSU variant. The three standard builds shown below are examples from the series and are not a one-to-one part-number cross-reference. Contact our engineering team with your original part number to obtain the matching specification, pinout and outline drawing, or to request evaluation samples.

Würth Elektronik and WE-AGDT are trademarks of their respective owner. These references identify alternative sourcing options; the products supplied are manufactured by TrafoPSU.

⚡ Belangrijkste elektrische specificaties

ParameterSpecificatieOpmerkingen / Testomstandigheden
Core / constructionEP7 ferrite, split bobbinTwo separate winding chambers
BobbinSMD EP7, 8 pins (4+4)Lead-free solder termination
Primary inductance50 µH min10 kHz, 0.1 V
Interwinding capacitance CWW3.0 pF typ.100 kHz, 10 mV
Turns ratio tolerance±2 %Across the series
Dielectric withstand4.0 kVAC, 3 mA leakage50 Hz, core to coil, 2 s
Isolated winding wireFIW4 triple-insulated, Ø0.18 – 0.20 mmReinforced-insulation system
Barrier filmPolyimide, 13 × 14.2 × 0.1 mmBetween chambers
Bonding / fixingEpoxy 808A/B-H, polyester tape 0.025 × 6.5 mmRoHS / REACH conformant
Operating temperature Top−40 °C to +125 °CComponent
Ambient temperature Ta−40 °C to +70 °CApplication level
Storage temperature Tst−40 °C to +85 °CUnpacked

Standard builds

BuildVin → VoutOutput powerTurns ratio N1:N2Leakage inductance (max)DCR N1 / N2 (max)
EP7 24 V / 20 V24 V → 20 V6 W1.2 : 11.95 µH85 mΩ / 85 mΩ
EP7 24 V / 12 V24 V → 12 V5 W1 : 0.51.50 µH85 mΩ / 85 mΩ
EP7 24 V / 48 V24 V → 48 V5 W1 : 23.00 µH85 mΩ / 160 mΩ

Leakage inductance measured at 100 kHz / 0.1 V with the secondary shorted. Primary winding: UEW, 155 °C, Ø0.18 mm × 2P. Other ratios and power levels on request.

Outline

DimensionValue
Length × width × height13.0 ± 0.2 × 14.2 ± 0.2 × 12.0 mm max
Pin pitch2.50 ± 0.2 mm
Pin row spacing8.69 ± 0.5 mm
Mounting8 pins (4+4), SMD

🛠️ Technische hoogtepunten & uitmuntend vakmanschap

1. Reinforced insulation built into the winding

FIW4 triple-insulated wire on the isolated winding, the bobbin chamber wall and the polyimide barrier film together form a single insulation system rated to the same protection level as double insulation — recognised as solid insulation under IEC 62368-1 Annex J. No second protective layer elsewhere in the design is required.

2. Barrier capacitance set by geometry, not by luck

Because primary and secondary sit in separate chambers, CWW is defined by the bobbin itself. At 3.0 pF typical it stays there part to part, instead of drifting with winding tension and lay-up — which is what usually happens when the two windings share one bobbin with margin tape between them.

3. ±2 % turns-ratio control

The bias rail follows the turns ratio directly. Holding it to ±2 % keeps the driver supply inside its window across production, without trimming the secondary regulator.

4. Built for the board it goes on

Epoxy-bonded and tape-secured core, polyimide barrier, lead-free terminations and an 8-pin layout with 2.50 mm pitch and 8.69 mm row spacing that follows the standard EP7 gate-drive footprint — so existing EP7-based layouts can generally be re-used. Verified across −40 °C to +125 °C.

🎯 Typische toepassingen

  • Gate driver bias supplies — isolated bias rails for high-side IGBT, SiC MOSFET and GaN stages
  • LLC resonant and half-bridge converters — including open-loop LLC bias designs built around driver ICs such as the TI UCC25800-Q1
  • EV charging and traction — on-board chargers, traction inverters and DC-DC converters
  • Industrial power — motor drives, UPS, welding inverters, solar inverters and server PSU auxiliary rails